MSR112 Port Powered Magnetic Strip Reader
| FEATURES
Compact size - can be mounted on keyboard or any flat surface
Software and hardware modification not required
Single, dual and triple track decoding
Bi-directional card swipe and read capability
Led indications: LED Off: swiping card & sending card data; Green:
stand-by.
Data rate: 9600 baud rate, none parity, 8-bit, 1 stop bit
No extra power supply is needed.
|

Click on the picture to enlarge |
CONFIGURATION
- MSR112-12 Dual track 1&2
- MSR112-23 Dual track 2&3
- MSR112 -33 Triple track 1&2&3
Note: Optional configuration is available.
SPECIFICATIONS
|
Recording Method |
Two-frequency coherent phase (F2F), compatible with ISO
7811 and AAMVA. |
|
Swipe Speed |
5 to 50 in/sec (worst case with +/- 12% jitter card) |
|
Power Requirements |
3.3VDC/4.9mA in idle mode; 5.9mA in operating mode
|
|
Operating Temp |
-10° C to +50°
C, storage temp: -30° C to +70°
C |
|
Operating Humidity |
10% to 85% relative humidity |
|
Magnetic Head Life |
500K swipes minimum. 500K, 1M option. |
|
Dimensions |
3.94 in L x 1.34 in W x 1.10 in H |
|
Weight |
0.46 Lb. |
|
Cable length |
5 ft |
|
Connector |
9 pin D-sub female |

OUTPUT DATA FORMAT
|
Single track |
<STX><SS>< TRACK 1or 2or 3 DATA><ES><ETX> |
|
Dual track |
<STX><SS>< TRACK 1 or TRACK 2 DATA><ES><DLE> |
|
<SS><TRACK 2 or TRACK 3 DATA><ES><ETX> |
|
Triple track |
<STX><SS><TRACK 1
DATA><ES><DLE><SS><TRACK 2 DATA><ES><DLE> <SS><TRACK 3 DATA><ES><ETX> |
Remarks:
SS = START SENTINEL
TRACK1= "%" (ISO, DMV & AAMVA)
TRACK2= ";" (ISO, DMV & AAMVA)
TRACK3= ";" (ISO) "%" (AAMVA) "!" (CA old DMV)
Note: TK3 SS can be replaced to + for ISO, # for AAMVA, and ! for CA old DMV
while SS is enable.
ES = END SENTINEL
TRACK1, 2 & 3= "?" (ISO, CA old DMV & AAMVA)
Note: 1. If read error, the default output data format is <STX><SS>E<ES><ETX>
and it can be replaced as either
<STX><SS>F<ES><ETX> or output nothing.
2. If no data is read, then display <STX><SS>N<ES><ETX> as default and it
can be replaced as output nothing.
3. <STX>, <ETX>, <DLE>, SS (start sentinel), ES (end sentinel) and LRC are
optional.
The <DLE> is programmable by command setting.
WARRANTY
This product is served under one-year warranty to the
original purchaser. Within the warranty period, merchandise found to defective
will be repaired or replaced. This warranty applies to the products only under
the normal use of the original purchaser, and in no circumstances covers
incidental or consequential damages though consumers’ misuse or modification of
the products.
|